Modifications in Canal Anatomy of Curved Canals of Mandibular First Molars by two Glide Path Instruments using CBCT ZC013-ZC017
Correspondence
Dr. Anil Dhingra,
B-3, New Multan Nagar, New Delhi -110056, India.
Phone : 09868087459, E-mail : dranildhingra39@gmail.com)
Background: The creation of glide path reduces the risk of instrument breakage. Glide path is created before using NiTi rotary instrumentation.
Aim: This study compared the changes in the root canal anatomy after creation of glide path using Path Files (PF) and V Glide Path 2 (VGP2) using Cone Beam Computed Tomography (CBCT).
Materials and Methods: Hundred extracted mandibular first molars with curved mesial roots, curvature angles ranging within 20-30 degrees were assigned into two groups (n = 50 each). Glide path was prepared using PF (Group I) and VGP2 (Group II). CBCT images were obtained before and after instrumentation. The technical outcomes were compared at 0, 1, 2, 3, 5 and 7mm intervals. The data was analyzed using t-test and Chi-square test.
Result: There was a statistical difference between the root canal curvatures and working time between the two groups (p < 0.05). Canals transported towards the distal side in Group II but there was a slight mesial transportation in Group I at 0mm. Group I exhibited a better centric ability except at 1mm interval (p > 0.05). The changes in the volume were statistically significant only at 2mm interval (p < 0.05). The difference in the cross sectional area was not statistically significant at any interval (p > 0.05).
Conclusion: Within the limits of this study the rotary Nickel Titanium Path Files appeared to be suitable instruments for safe and easy creation of glide path.